Robotics Power Supplies: How Do 48V and 24V Architectures Respond to Actuator Loads?

QUICK LINKS

Quick answer: A 48V distribution bus feeding local 24V conversion and a centrally distributed 24V bus expose different parts of a robotic system to the actuator's current demand. The correct choice depends on distribution impedance, converter behavior, required power, mechanical integration and the actual operating profile. A 2026 TI reference design illustrates one local step-down architecture, not a validated Phihong robotics system.

Why This Topic Matters Now

Compact robotic equipment may contain actuators, sensors, processors and communications hardware with different voltage and transient requirements. A shared supply can see the combined effect of those loads. Moving conversion closer to an actuator may change the current carried by the upstream wiring, but adds a local converter and its own operating restrictions. The design question is not simply whether 48V is better than 24V. It is where power is converted, where it is stored and which electrical path must support each operating state.

Source context: TI PMP31431 reference design.

How Does Distribution Voltage Affect Current?

For an idealized 240W transfer, 24V corresponds to 10A and 48V corresponds to 5A. At a fixed distribution resistance, the lower current reduces resistive loss in that path. Real equipment also has conversion losses, voltage tolerance, connector limits and protection requirements. A higher bus voltage does not automatically improve the complete system's efficiency or establish safety suitability. The example identifies one reason an engineer may consider distributing at a higher voltage and converting locally. The actual design needs its own loss and operating-state assessment.

Engineering workflow: Actuator power architecture

  1. 01
    Distribution source
  2. 02
    Bus boundary
  3. 03
    Local converter
  4. 04
    Actuator operating state
  5. 05
    System validation
Illustrative review workflow, not a measured result or prescribed compliance procedure.

What Does TI's March 2026 Reference Design Illustrate?

TI's PMP31431 reference design is a compact 48V-to-24V GaN buck converter with documented performance and load-transition waveforms. The report identifies distinct output-current transitions and operating modes. This provides a concrete illustration of a downstream conversion stage, including why its own transient response matters. The published results apply to TI's reference hardware and conditions. They should not be attributed to a Phihong AC/DC product or treated as validation of an arbitrary actuator.

Where Should Engineers Observe a Dynamic Load?

The actuator-side current is not necessarily the same as the upstream supply current because local conversion and stored energy affect the relationship. Observe the appropriate source and load boundaries and identify the conversion mode. Consider combined demand when several actuators operate concurrently. A test on one isolated channel may omit the condition experienced by a common bus. Keep a representative sequence of permitted actuator operations, controller state and observed rail behavior. The mechanical workload and control system define the application demand; an electrical supply label does not.

What Should Be Reviewed About Energy Returned by a Load?

Some actuator systems can return energy to their local DC path during particular operating states. The responsible system engineer should determine whether that occurs and establish the approved handling of the returned energy. Do not assume a conventional supply can absorb arbitrary reverse energy. The applicable converter and protection documentation must support the intended behavior. Keep regeneration questions separate from positive output peak-power claims. A qualification record should identify any permitted operating state in which reverse energy or bus rise is relevant and the documented system-level acceptance boundary.

How Should Product Selection Follow the Architecture Decision?

Phihong's product portfolio includes 24V and other industrial output options. The published 240W BI240 model illustrates a documented 24V source, not an actuator-qualified architecture by itself. Some 24V and 48V open-frame variants also appear on the company's coming-soon page, so confirm current release status and model documentation before selection. An OEM should establish whether the proposed source supports the actual bus load and whether downstream conversion, energy handling and equipment integration meet the application requirements. A research article can explain architectural tradeoffs without claiming a specific robot or actuator is supported.

Review the relevant documentation

Compare the exact model, operating conditions and revision before drawing conclusions for an OEM application.

Phihong technical documentation

Worked Example: What Changes When Distribution Voltage Doubles?

Consider a hypothetical 240W delivered to a load, ignoring conversion losses for the moment. At 24V the associated current is 10A; at 48V it is 5A. If the same simplified distribution resistance were 0.1 ohm, the corresponding resistive losses would be 10W and 2.5W. The arithmetic illustrates why higher-voltage distribution can reduce current-related loss along a particular path. It does not establish an efficiency advantage for the complete equipment. A 48V architecture feeding a 24V actuator also requires appropriate conversion and integration, with its own loss, operating limits and protection considerations.

The real comparison must include the complete power path, not just a single cable. Consider the source's operating range, converter input requirements, local load conditions and the characteristics of the connecting path. The equipment engineer should determine the acceptable voltage behavior at the actuator and upstream source. A design that reduces distribution current may still be unsuitable if the converter cannot satisfy the actuator's required operating state. Likewise, a direct 24V architecture may be appropriate for a compact system with a different distribution and integration requirement.

How Can Local Storage Change the Source's Observed Demand?

An actuator-side event may be supported partly by local storage, the downstream converter and the upstream source. Their contributions depend on the architecture and event time scale. A measurement at the actuator does not automatically describe the current drawn from the upstream supply. The appropriate source test should reflect the demand at its own boundary. A separate local-rail test may be needed to evaluate the actuator input. Distinguish those requirements instead of applying the same numeric current to every point in the system.

The initial state of storage and the preceding load sequence can also matter. A one-time event after a long interval may not represent repeated events during continuous equipment operation. Characterize the actual sequence and identify the operating state at the beginning of the observation. The companion pulse-load and thermal-loading articles discuss repetition and prior state. This architecture article uses those principles to identify where the relevant load is seen rather than assuming that the power rating alone answers the distribution question.

What Does a Multi-Axis Equipment Review Need to Capture?

A robot may perform several actions in a coordinated sequence. Even when each actuator's demand is understood separately, the shared source requirement depends on how the events overlap and how the distribution system responds. Document the representative equipment states and identify which load combinations are relevant to the intended application. Do not assume that every nominal maximum occurs at the same time, and do not ignore potential overlap simply because individual tests pass. The equipment controller and mechanical use case determine the relevant operating sequences.

Where a local converter is used, preserve its operating mode and documented limits with the measured source profile. A reference design such as TI's 48V-to-24V converter can illustrate the role of local conversion, but its measured waveforms do not qualify an arbitrary robotic system. An OEM should validate the chosen source, converter and equipment combination against the defined requirements. The report should distinguish published reference data from project-specific evidence.

How Should Procurement Compare a 24V Source With a Distributed Architecture?

The purchasing request should identify whether the source feeds a 24V load directly or a different bus with downstream conversion. Include the relevant source-side continuous demand, transient conditions, installation environment and equipment requirements. If energy can return toward the power path, ask the responsible system engineer to establish the approved handling and applicable component capabilities. A conventional source's positive power rating should not be used as evidence of reverse-energy capability.

Phihong's 24V industrial models can provide a documented starting point where their actual conditions match the application. A potential 48V or other variant should be checked against its current release status and documentation before being presented as an available choice. A useful procurement disposition identifies the approved architecture and model, any additional conversion or system evidence needed and the responsible decision owner. It does not rely on the general assumption that one distribution voltage is universally better for robotics.

What Evidence Belongs in the OEM Release Record?

A robotics procurement decision needs the expected operating sequence, not simply the total motor nameplate power. Two axes moving together can present a different bus demand from two axes moving in succession. The local converter, distribution conductors and any energy storage influence the stimulus seen by the upstream supply. When the application can return energy to a bus, the system designer must establish the permitted behavior and handling method; a conventional output power rating does not establish sink capability. Compare candidate architectures at the same required mechanical and electrical operating states and document the conditions that differ. A third-party reference design illustrates an architecture, not an approved Phihong robotics implementation.

Review item Evidence to retain Decision criterion
Power distribution Bus voltage, current demand and local conversion boundaries Evaluate the complete power path rather than an adapter rating
Operating state Representative actuator workload and simultaneous demand Separate peak, sustained and recovery states
Returned energy Applicable system behavior and handling assumptions Do not assume a source can absorb energy unless specified
Qualification Measured bus and local rail evidence Compare architecture-specific conditions and model limits

Key Takeaways

  • Power distribution: Evaluate the complete power path rather than an adapter rating
  • Operating state: Separate peak, sustained and recovery states
  • Returned energy: Do not assume a source can absorb energy unless specified
  • Qualification: Compare architecture-specific conditions and model limits

Frequently Asked Questions

Is a 48V architecture automatically more efficient?

No. Compare total conversion and distribution losses.

Can source current be inferred directly from actuator current?

Not without considering conversion and storage.

Does a positive peak-power rating establish reverse-energy capability?

No. Verify the relevant system design and documentation.

Does a reference converter design establish qualification of a commercial supply?

No. The reference design results belong to its own implementation.