Convection Cooling: Where Should You Measure Temperature Around a 3×7-Inch Power Supply?
QUICK LINKS
A temperature measured outside an industrial cabinet does not describe the air surrounding an open-frame power supply. A nearby drive, wiring duct or door barrier can create a warmer pocket or interrupt the airflow that was available in a laboratory setup. A useful temperature map tells engineering what the supply experienced in the installed machine and why.
Quick answer. Record room temperature, local upstream and downstream air around the supply and the conditions at the nearest relevant heat source. Measure in the production orientation, with representative neighboring equipment and duty. Use the BI150-240A-R datasheet to interpret the applicable operating and derating conditions.
Why This Topic Matters Now
Open-frame supplies rely on their installation for the environment around the board. A retrofit may keep the original enclosure while changing a bracket, cable duct or component orientation. Those changes can affect the thermal result even when the new supply operates within electrical limits on a bench.
Think of the cabinet as a system with several heat sources and several paths for air. A room thermostat tells you the broader test environment. The temperature of air approaching the supply is the more relevant measurement for comparing installed conditions with a datasheet boundary.
For the wider decision, start with the complete retrofit qualification process. Then connect this result with startup demand and operating duty. The earlier industrial retrofit guide provides the broader engineering background.
- Define the machineLoad, cabinet and installation requirements
- Evaluate the retrofitFit, startup, temperature and EMC
- Release the configurationApproved supply, harness and service record
Conceptual qualification workflow. Each result belongs to the exact tested configuration.
Where should air temperature be measured?
Place a room reference where it represents the environment around the cabinet. Inside, select an upstream point representative of the air approaching the supply’s local area and a downstream point where the warmed air leaves that area. Define those locations for the actual orientation instead of assuming that the same points apply after moving the supply from horizontal to vertical. Document sensor position and distance from nearby surfaces.
| Point | Decision it supports |
|---|---|
| Room reference | Confirms the external test condition |
| Local upstream air | Helps interpret the supply’s local operating environment |
| Downstream air | Reveals local temperature rise or a constrained exit path |
| Nearby load or wall | Helps isolate heat contributions and airflow restrictions |
An air sensor touching a board or enclosure wall measures a different condition. If a compliance or reliability plan calls for an approved component or surface measurement, keep that reading identified separately. Do not substitute a surface temperature for the ambient variable in the datasheet.
What should the enclosure and duty look like during the test?
Use the production plate, barriers, harness, cover and relevant option modules. Include neighboring devices that produce heat in the same operating sequence. If the cabinet normally operates closed, capture the closed condition with a sensor arrangement that preserves the relevant geometry. An open-door diagnostic run can help explain a difference, but it should have its own label.
| Test configuration | Record |
|---|---|
| Representative normal duty | Load profile, adjacent equipment and cabinet condition |
| Worst credible sustained mode | Duration, electrical output and stabilized local air |
| Repeating duty | Cycle timing, peak and recovery trend |
| Cabinet variants | Orientation, clearances and shielding or duct differences |
Make the electrical measurements and thermal timing comparable. A temperature trace without the load profile may leave the team unable to distinguish self-heating from adjacent loads. Similarly, a single stabilized value can hide a repeated cycle that creates a new peak when several loads coincide.
How do you turn measurements into a release decision?
Use the datasheet boundary for the exact model, installation and operating conditions, then compare it with the measured local environment and output duty. Include uncertainty and the configuration differences that are expected in production. The BI150-240A-R product page identifies the family and application, while the model-specific documentation provides the operating conditions used in the engineering assessment.
If readings are unexpectedly high, change one variable at a time where practical. Move a wiring duct only in a controlled test configuration. Compare the upstream and downstream signals, then document why the new layout produces an acceptable result. An improvement in a single location may redirect heat toward a neighboring component.
When should an OEM repeat the thermal assessment?
Repeat or review the assessment when changes affect a relevant heat source, the airflow path or the rated operating condition. A different bracket can move the supply into a warmer region. An added option may change both the load on the rail and the heat adjacent to the board. Treat a cabinet revision as a potential test configuration rather than assuming the approval transfers.
| Change | Why it matters |
|---|---|
| Supply orientation | Can change the way heated air rises around the board |
| Harness or barrier position | May constrain local airflow |
| Added equipment or output duty | May increase internal heat or rail demand |
| Room environment or installation | May shift the thermal boundary for the enclosure |
Key Takeaways
Map temperature at named locations in the real enclosure. Preserve the load and sensor history, apply the exact model’s operating conditions and define which cabinet configurations the evidence covers.
Product and OEM Resources
FAQs
Is room temperature enough for a convection assessment?
Room temperature is a reference. Record the supply’s local air conditions when the enclosure and nearby components can make them different.
Can a sensor at the top of the cabinet represent the supply inlet?
Only if the position represents air approaching the supply in that configuration. A sensor in a warm outlet region describes a different condition.
When is a test long enough?
Use the thermal stability or repeating-cycle criterion approved for the machine. Record the criterion and the operating duty with the results.